Trolmaster Dual Condition Adaptor for Hydro-X system

DCC-1
$63.00
Dual Condition Adaptor (DCC-1) The TrolMaster DCC-1 provides a simple solution to control a single device, with more than one condition. For example, people like to turn on their exhaust fans when either temp or humidity is too high; shut off CO2 when turn on exhaust fans. There are many other examples where two conditions can be either combined or split.  The DCC-1 is designed to be used in combination with one of TrolMaster’s plug-in style module. (DSC-1, DSH-1/2, DST-1/2 and DSP-1).  Once connected to the plug-in module using the RJ12 cable built-into the DCC-1, the DCC-1 will act in concert with that plug-in module to control whatever device is connected to the plug-in module.  The DCC-1 can also be set to work in two distinct ways u...Show More >

Dual Condition Adaptor (DCC-1)

The TrolMaster DCC-1 provides a simple solution to control a single device, with more than one condition. For example, people like to turn on their exhaust fans when either temp or humidity is too high; shut off CO2 when turn on exhaust fans. There are many other examples where two conditions can be either combined or split. 

The DCC-1 is designed to be used in combination with one of TrolMaster’s plug-in style module. (DSC-1, DSH-1/2, DST-1/2 and DSP-1). 

Once connected to the plug-in module using the RJ12 cable built-into the DCC-1, the DCC-1 will act in concert with that plug-in module to control whatever device is connected to the plug-in module. 

The DCC-1 can also be set to work in two distinct ways using the “Interlock” function.

INTERLOCK OFF: When the DCC-1 interlock is set to be off, EITHER condition that are associated with that pair of modules that are being used together can be activated individually for the device to be activated. (modules used in “parallel”)

Examples from above for interlock OFF would be:  

  • Turn on an exhaust fan to reduce temp or humidity.
  • Turn on an exhaust fan at night using a recycling timer OR when Humidity is too high

INTERLOCK ON: When the DCC-1 Interlock is selected to be on, BOTH conditions that are associated with that pair of modules that are being used together must be activated TOGETHER in order for the device to be activated. (modules used in “series”)

Examples from above for interlock ON would be:  

  • Shut off a CO2 device when an exhaust fan is running
  • Shut off lights if the temperature gets too warm within the area.

< Show Less
$63.00

    You have added a Discontinued Item.

    Please keep in mind the inventory quantity listed on discontinued items is not always accurate and these items may be out of stock at any time.

    Certain items may not be supported by the manufacturer and warranties could be limited.

    Contact Agron Customer Support for additional questions.

    support@agron.io
    877.812.4766

    Don't show this message again, I know 'Discontinued Items'.

    WHY SHOP WITH AGRON?

    SMOOTH DELIVERY

    SMOOTH DELIVERY

    REAL TIME INVENTORY

    REAL TIME INVENTORY

    SIMPLE RETURNS

    SIMPLE RETURNS

    INDUSTRY EXPERTS

    INDUSTRY EXPERTS

    You recently viewed

    Clear recently viewed
    Loading…
    We use cookies to ensure that we give you the best experience on our website. If you continue we will assume that you understand this. Learn more
    Accept